Megger delta 2000 manual

External laptop is easily placed on top surface of module for added convenience. Test mode set the test mode, suppress set suppression onoff d2000d3000 or. Transformer and substation test system postal address egger seden a ox 2 s182 1 dandrd swdn t 8 10 19 00 f 8 10 19 9. Megger delta 2000 general equipment other types of equipment. The megger mit4102 insulation tester is a versatile instrument that offers testing from 50 to v and 200g though the mit4102 is designed primarily for industrial applications, it offers a wide range of functions that allow it to excel in an exceptionally wide range of applications including electrical installations, cable testing, motor testing, automotive, esd, panel building. Optional bar code wand and pc software for recording an alphanumeric test identification in the field.

Megger tdr20003 advanced dual channel tdr datasheet. Megger limited archcliffe road dover kent ct17 9en england. Tdx120 accessory for tan delta power factor up to 12 kv tcx200 high current accessory for primary injection testing up to 2000 a tsx303 automated 3phase switchbox for faster testing of power transformers tsx300 manual switchbox for easier connection during power transformer testing. Megger operating manuals official distributor for megger. Its unique combination of test capabilities and artificial intelligence analysis software makes it the power industrys most trusted power factortandelta instrument. Allen industries offers expert megger delta 2000 repair and calibration. Used avo megger bgl dc battery ground fault locator. Measured quantities include voltage, current, power loss, power factor. Delta4000 series 12 kv insulation diagnostic system megger. Instruction manual for delta2000 powerpoint engineering. At megger we dedicate ourselves to improving electrical safety for our customers performing electrical. We use cookies to provide you with a better experience. To find out more, please visit to learn more about us.

Its unique combination of test capabilities and artificial intelligence analysis software makes it the power industrys most trusted power factortan delta instrument. Delta4000 series is a fully automatic 12 kv insulation power factor dissipation factor tan delta test set designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arresters, and rotating machinery. Multifunction transformer and substation test system megger. Extremely easy to use, without any extensive hardware or software setup. This set has been designed to provide a comprehensive ac insulation diagnostic test. Under the megger calibration authorized service agreement jm test can service insulation testers, micro ohmmeters, multifunction meters, ground testers, and oil cup testers oil tan delta, all of the 5kv megohmmeters, 10kv megohmmeters, dlros insulation resistance testers, high performance diagnostic insulation testers, time domain reflectometers, multifunction. Designed for the location of faults communication and pilot cables and some power supplies the tdr20003 and tdr2010 are tough. Megger delta2000 calibration services total calibration.

Delta2000 can be used for measuring the excitation current of. M valley forge corporate center 2621 van buren avenue norristown, pa 194032329 u. Measurements include voltage, current, power loss, tan delta, inductance, power factor and capacitance. Megger sweden ab is certified according to iso 9001 and 14001. Delta 2000 10 kv automated insulation power factor test set rs232 serial interface for downloading the test results to a pc. Delta 2000 10 kv automated insulation power factor test set description the delta 2000 is a fully automatic 10 kv insulation power factor test set designed for condition assessment of electrical insulation in high voltage apparatus, such as transformers, bushings, circuit breakers, cables, lightning arresters and rotating machinery. Trax electrical test equipment power station to plug megger. Individual temperature correction itc megger innovation for more accurate insulation properties at reference temp 20 c when measuring warm or cold objects. The complete guide to electrical insulation testing. Megger delta 2000 repair delta 2000 repair megger delta. Megger finally refunded our money but only after a long draw out dialog. Fullyautomatic power factor test set also known as the delta 2000.

There is direct readout of tan delta, capacitance and watts dissipated. Megger delta 4110 12 kv insulation diagnostic system the delta4000 is used for shop and field testing of highvoltage electrical insulating systems at test voltages up to 12 kv. Instruction manual for delta 2000 10kv automated insulation test set catalog no. The delta 2000 is a fully automatic 10 kv insulation power factor test set designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arrestors and rotating machinery. Megger delta 4000 reference manual pdf download manualslib. Via powerdb software, ttr testing is in accordance with megger ttr300 product specifications. The delta4000 series can also be used with delta control software in a. The delta2000 is a fully automatic 10 kv insulation power factor test set. It is compatible with megger powerdb software for automated testing solution. F sept 2008 instruction manual delta 3000 10kv automated insulation test set catalog no. Visiting address egger seden a rinkebyvgen 19 s182 dandrd swdn registered to iso 001 and 1001 megger is a registered trademark printed matter.

Megger delta 4000 manuals manuals and user guides for megger delta 4000. The megger delta 2000 10kv automated insulation power factor test set is an extremely easytouse test equipment with no extensive hardware or software setup. Com reference manual applications guide delta 4000 12 kv insulation diagnostic system zmah02e. Megger 672001 delta2000 automated insulation power factor. Calibration report used megger bite 3 battery impedance tester. Includes a batteryline operated printer for a hard copy of the test results. Megger delta 2000 automated insulation power factor test set. Total calibration solutions offers accredited instrument calibration services for the megger delta 2000 10kv automated insulation test set. Megger operating manuals official distributor for megger in. Atec megger delta2000 user manual atec equipment 10 kv automated insulation power factor test set designed to work in high interference switchyards of up to 765 kv builtin capability for storing, pri. The resonating inductor is a selfcontained, airinsulated tool which allows the user to perform capacitance and dissipation factor tests on highcapacitance items such as. The m4100 is the industry standard for power apparatus and insulation testing. They are rated to cat iv 150 v and are dust and weatherproof to ip54, so there are ready to work in the real world. Delta2000 10 kv automated insulation power factor test.

Tan delta test attachment integral cable diagnosis system. Lcb20002 and lcb25002 combined rcd and loop testers megger. The delta4000 series operates with powerdb software for automatic testing and reporting or with delta control software for realtime manual testing. Bottom line, we should have not strayed away from doble. Delta4000 series 12 kv insulation diagnostic system maxicont. Megger delta 2000 power factor test set problems we recently purchased a megger delta 2000 power factor test set and experienced problems immediately. Leakage reactance tester, 120 v ac, 5060 hz mlr10 leakage reactance tester, 240 v ac, 5060 hz mlr1047 included accessories output leads, 50 ft 15 m 2000 876 ground lead, 15 ft 4. Megger delta 2000 power factor test set problems electric.

Megger delta 2000 power factor test set megger delta 3000 10 kv automated insulation power factor test set megger delta4000 series 12 kv insulation diagnostic system megger delta4310 12kv insulation diagnostic system megger idax300 insulation diagnostic analyzer. Transformer and substation test system q eighty united. Megger delta 4000 reference manual 48 pages 12 kv insulation diagnostic system. Megger mit4102 insulation tester insulation testers. Total calibration solutions is an isoiec 17025 and ansincsl z54011994 accredited ohio based calibration company. Item has been replaced by a newer model get new model the delta 2000 is a fully automatic 10 kv insulation power factor test set designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arrestors and rotating machinery.

Tan delta power factor testing at 12 kv and 500 ma for high capacitance tests without the use of an external inductor. Our repair and calibration service includes many manufacturers and models of the many ohmmeters on the market, both current and discontinued. Delta2000 10 kv automated insulation power factor test set. Test results can be used to evaluate the nature and quality of electrical insulating materials and manufacturing processes to reveal contamination, fractures, punctures. We have 1 megger delta 4000 manual available for free pdf download. The delta 2000 is a fully automatic 10 kv insulation power factor test set designed for condition assessment of electrical insulation in high voltage apparatus. For good insulation, the resistance usually reads in the megohm range.

F sept 2008 instruction manual delta3000 10kv automated insulation test set catalog no. Megger representative for instructions and a return authorization ra number. This user manual describes the operation and functions of the det series of earth ground testers. Megger delta2000 power factor test set is a fully automatic test set has been designed to provide a comprehensive ac insulation diagnostic test for high voltage apparatus, such as transformers, bushings, circuit breakers, cables, lightning arrestors and rotating machinery. The contents of this manual are the property of megger sweden ab. Megger delta2000 10kv automated insulation power factor. Capacity boost for insulation diagnostics by reducing test frequency and voltage via megger delta 4000 tand test set. Megger delta 4110 12 kv insulation diagnostic system description the delta4000 series is a fully automatic 12 kv insulation power factordissipation factor tan.

Megger delta 4110 12 kv insulation diagnostic system. The megger delta 2000 is a fully automatic 10 kv insulation power factor test set designed for condition assessment of electrical insulation in high voltage apparatus, such as transformers, bushings, circuit breakers, cables, lightning arresters and rotating machinery. It is designed to work in high interference switchyards of up to 765 kv. M4100 power factortandelta instrument doble engineering. Megger delta 2000 power factor test set is a fully automatic test set has been designed to provide a comprehensive ac insulation diagnostic test for high voltage apparatus, such as transformers, bushings, circuit breakers, cables, lightning arrestors and rotating machinery. Motor and phase rotation tester 5060 hz 560060 255060400 hz 560400 included accessories attached test leads line, 6 ft 1. Megger delta 4110 insulation diagnostic transformer testers. Avo international po box 9007 valley forge, pa 194851007 u. Megger operating manuals megger user manuals official.

The megger insulation tester is a small, portable instrument that gives you a direct reading of insulation resistance in ohms or megohms. First section identified in a 9wire, 3 delta motor 1b 1a 1c c a b a c b item qty cat. Delta2000 10 kv automated insulation power factor test set the optional oil test cell, cn 670511, is used for testing insulating fluids up to 10 kv optional ttr300d module, for lv threephase ttr testing, installed inside delta hv cabinet. View and download megger delta 4000 reference manual online. Extremely easy to use, without any extensive hardware or software setup s. Contact your megger representative for instructions and a return. Megger delta 2000 repair delta 2000 repair megger delta 2000. The megger insulation tester is essentially a highrange resistance meter ohmmeter with a builtin directcurrent generator. Integrated powerdb software package allows for automated control without the use of a laptop. The user simply selects the test object and the unit will automatically run the complete test and report the results back to the test form. Delta 4000 testimonials from customers in the indian subcontinent. May 10, 2012 delta4000 series is a fully automatic 12 kv insulation power factor dissipation factor tan delta test set designed for condition assessment of electrical insulation in high voltage apparatus.

171 1398 481 1340 1020 1069 659 996 1182 32 741 413 1055 1585 249 35 804 1296 362 1426 215 840 1400 1 439 490 1297 860 1358 1292 425 792 1101 896 242 1238